Monitoring Configure NetFlow Probe
Digi Connect IT® 16/48 User Guide
632
11. Add collectors:
a. Click to expand Collectors.
b. For Add Collector, click .
c. (Optional) Type a Label for the collector.
d. For Address, type the IP address of the collector.
e. (Optional) For Port, enter the port number used by the collector. The default is 2055.
Repeat to add additional collectors.
12. Click Apply to save the configuration and apply the change.
Command line
1. Log into the Connect IT 16/48 command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. Enable NetFlow:
(config)> monitoring netflow enable true
(config)>
4. Set the protocol version:
(config)> monitoring netflow protocol version
(config)>
where version is one of:
n v5—NetFlow v5 supports IPv4 only.
n v9—NetFlow v9 supports IPv4 and IPv6.
n v10—NetFlow v10 (IPFIX) supports both IPv4 and IPv6 and includes IP Flow Information
Export (IPFIX).
The default is v10.
1. Enable flow sampling by selecting a sampling technique. Flow sampling can reduce flow
processing and transmission overhead by providing a representative subset of all flows.
(config)> monitoring netflow sampler type
(config)>