MTG2000 Trunk Gateway User Manual V| Dinstar
109
Belong to
Parameter
Explanation
WEB
Configuration
HTTP Port
HTTP port The default port of the HTTPS service
is 80.
HTTPS Port
HTTPS port The default port of the HTTPS
service is 443.
HTTPS Only
When enabled, the device cannot be accessed
using http.
HTTP HOST
Checking
In NAT environment, HTTP HOST verification is
made when enabled, and the device cannot be
accessed normally, but it can be accessed normally
when disabled.
HTTP X Frame
Options
When starting, add X-Frame-Options: sameorigin
to the http response message of the device.
Telnet
Configuration
Telnet Port
Local Telnet default port, which is 23.
System
Parameter
CPU Working
Mode
Configure CPU working mode, such as low
power/high performance.
E1 Call Limit
Configuration
Maximum
Number of Calls
The maximum number of calls within the
effective time, 0 means the function does not take
effect.
Effective time
The effective time to limit the maximum number
of calls, 0 means the function is not effective, and
the E1 call limit configuration takes effect for
each E1.
Access
Control
Web
Options for GE0/GE1 to access web.
Telnet
Options for GE0/GE1 to access telnet.
Ssh
Options for GE0/GE1 to access ssh.
SYSLOG
Configuration
SYSLOG
Enable
To send logs of the corresponding to the
SYSLOG server.
Log Type
The type of syslog, users can select signal syslog,
system syslog, management syslog and media
syslog.
Server IP1
The IP address of the SYSLOG server.
Server IP2
The IP address of the SYSLOG server.
SYSLOG Level
Configure Syslog Level, users can set five levels
such as NONE, DEBUG, INFO, NOTICE,
WARNING.
Send CDR
When enabled, the device will automatically send

Table of Contents