8-254
ENGINE ELECTRICAL
-
Ignition System
VW
gap
.’
gauge
easurement
rection
mJ
m
IELlOt
6ELOlOZ
INSPECTION
SPARK PLUG
Check plug gap using a plug gap gauge and adjust if it is not as
specified.
Standard value: 1.0
-
1.1 mm
(.040
-
.043
in.)
SPARK PLUG CABLE
(I) Check cap and coating for cracks.
(2)
Measure resistance.
Limit: Max. 22
kti
IGNITION,
POWER TRANSISTOR
NOTE
An analog-type circuit tester should be used.
(I) Connect the negative
(-)
terminal of the
1.5V
power supply
to terminal
@
of the ignition power transistor; then check
whether there is continuity between terminal
@
and
terminal
@
when terminal @and the positive (+) terminal
are connected and disconnected.
NOTE
Connect the
(-)
probe of the circuit tester to terminal
0.
Terminal 1 and
(+)
terminal Terminal 3 and terminal 2
Connected
I
Continuity
I
Unconnected
I
No continuity
I
(2) Replace the ignition power transistor if there is a malfunc-
tion.
IGNITION COIL
Primary Coil Resistance
Measure the resistance of the positive (+) terminal and
negative
(-)
terminal of the ignition coil.
Standard value: 0.72
-
0.88
IR
Secondary Coil Resistance
Measure the resistance of the positive (+) terminal and the
high-voltage terminal.
Standard value:
10.29
-
13.92 kR