Setup
Operating Instructions 867-M PREMIUM - 00.0 - 02/2015 61
7.13.2 Setting operating pressure
Proper setting
The operating pressure for the pneumatic unit is 6 bar.
Fig. 39: Setting operating pressure
1. Pull the pressure controller (1) up.
2. Turn the pressure controller until the pressure gage (2)
indicates 6 bar:
• To increase pressure: Turn the pressure controller (1)
clockwise.
• To reduce pressure: Turn the pressure controller (1)
counterclockwise.
3. Push the pressure controller (1) down.
NOTICE
Machine damage possible due to incorrect pressure.
Incorrect pressure can result in damage to the machine.
Make sure that the operating pressure is set correctly before
putting the machine into operation.
(1) - Pressure controller
(2) - Pressure gage