Operating Instructions 867-M PREMIUM - 00.0 - 02/201520
5.2 Inserting and replacing the needle
Sequence
After switching to a different needle size, adjust the distance
between the hook and the needle ( Service instructions).
Faults caused by an incorrect hook clearance
After inserting a thinner needle:
Missing stitches
Thread damage
After inserting a thicker needle:
Damage to the hook tip
Damage to the needle
WARNING
Risk of injury from needle and moving parts!
Turn the sewing machine off before replacing the
needle.
Do not touch the tip of the needle.
NOTICE
Damage to the machine, needle breakage, or thread dam-
age is possible due to incorrect distance between the
needle and hook tip.
Check the distance to the hook tip after inserting a new
needle with a different size. Reset distance if necessary.