 List of event codes
Information – 228
7.5.2 UPS(HID) alarm log codes
7.5.2.1 Critical
Code Severity Active message Non-active message Advice
002 Critical Internal failure End of internal failure Service required
004 Critical Temperature alarm Temperature OK Check air conditioner
100 Critical Rectifier fuse fault Rectifier fuse OK Service required
105 Critical Input AC module failure Input AC module OK Service required
207 Critical Bypass AC module failure Bypass AC module OK -
208 Critical Bypass overload No bypass overload -
305 Critical Rectifier failure Rectifier OK Service required
306 Critical Rectifier overload Rectifier OK Reduce output load
308 Critical Rectifier short circuit Rectifier OK Reduce output load
400 Critical DCDC converter failure DCDC converter OK Service required
500 Critical Battery charger fault Battery charger OK Service required
607 Critical Battery test failed Battery test OK Check battery
60D Critical No battery Battery present Check battery
61B Critical Battery BMS fault Battery BMS OK Check battery
629 Critical Battery voltage low critical Batteryvoltage OK Check battery
62B Critical Battery voltage high critical Batteryvoltage OK Check battery
62D Critical Battery charge current low critical Batterycharge current OK Check battery
62F Critical Batterycharge current high critical Batterycharge current OK Check battery
631 Critical Battery discharge current low
critical
Batterydischarge current OK Check battery
633 Critical Batterydischarge current high
critical
Batterydischarge current OK Check battery
635 Critical Battery temperature low critical Batterytemperature OK Check battery
637 Critical Batterytemperature high critical Battery temperature OK Check battery
63E Critical Battery fault Battery OK Check battery
704 Critical Inverter internal failure UPS OK Service required
705 Critical Inverter overload No power overload Reduce output load
706 Critical Temperature alarm Temperature OK Check air conditioner
70B Critical Inverter short circuit End of inverter short circuit Service required
805 Critical Output short circuit Output OK Reduce output load
This table applies to all UPS except to the 9130 UPS.
To retrieve Alarm logs, navigate to Contextual help>>>Alarms section and press the Download alarms button.
Below codes are the one to be used to add "Exceptions on events notification" on email sending configurations.
Some zeros maybe added in front of the code when displayed in emails or logs.