28 DC1 Variable Frequency Drive 04/16 MN04020003Z-EN www.eaton.com
When connecting multiple motors in parallel to the output of
a variable frequency drive, the motor currents are
added
geometrically
– separated by effective and reactive current
components.
When you select a variable frequency drive, make sure that it
can supply the total resulting current. It may be necessary to
install motor chokes or sine filters between the variable
frequency drive and the motor in order to dampen and
compensate for deviating current values.