6 Technical Data
6.7 Mains chokes
DC1 Variable Frequency Drive 04/16 MN04020003Z-EN www.eaton.com 151
6.7 Mains chokes
DX-LN1…
Figure 80: DEX-LN1… mains chokes (single-phase)
Table 27: Assigned mains chokes (single-phase)
For more information and technical data on DX-LN…
mains chokes, please refer to instruction leaflet
IL00906003Z.
Device Type
Input
current
Mains choke, single-phase
(U
LN
max. 260 V +10 %, 50/60 Hz ±10 %)
Type (max. 50
o
C) Type (max. 40
o
C)
I
LN
I
e
I
e
A A A
Mains voltage 115 V
Supply voltage (50/60 Hz) U
LN
110 (-10 %) - 115 (+10 %) V
U
e
115 V AC, single-phase / U
2
230 V AC, three-phase (internal voltage doubler)
DC1-1D2D3…
7.8 DX-LN1-009 8.1 DX-LN1-009 8.6
DC1-1D4D3…
15.8 DX-LN1-018 17.1 DX-LN1-018 18
DC1-1D5D8…
21.9 DX-LN1-024 22.8 DX-LN1-024 24
Mains voltage 230 V
Supply voltage (50/60 Hz) U
LN
200 (-10 %) - 240 (+10 %) V
U
e
230 V AC, single-phase / U
2
230 V AC, three-phase
DC1-122D3…
3.7 DX-LN1-006 5.5 DX-LN1-006 5.8
DC1-124D3…
7.5 DX-LN1-009 8.1 DX-LN1-009 8.6
DC1-127D0…
12.9 DX-LN1-018 17.1 DX-LN1-013 13
DC1-12011…
19.2 DX-LN1-024 22.8 DX-LN1-024 24
DC1-12015…
29.2 DX-LN1-032 30.4 DX-LN1-032 32