Page #10 background imageLoading...
Page #10 background image
9
3. Never position the inverter in direct sunlight. Please refer to the figure below and choose a well-
shaded site or a shed to protect the inverter from direct sunlight. PROTECT the LCD screen from
excessive UV exposure.
4. The inverter should be installed upright on a vertical surface.
4.2.2 Installing the Inverter
The inverter is designed to be wall-mounted and should be installed on a vertical, solid, mounting sur-
face, such as brick, concrete, or other non-combustible material. Two or more people may be needed
to install the inverter due to its weight. The slots on the mounting bracket can accommodate various
stud spacings from 12 in. (305 mm) to 16 in. (406 mm).

Table of Contents

Other manuals for EG4 18KPV

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EG4 18KPV and is the answer not in the manual?

EG4 18KPV Specifications

General IconGeneral
ModelEG4 18KPV
CategoryInverter
Rated Power18 kW
Max. AC Output Current75A
Surge Power36 kW
Number of MPPTs2
Frequency50/60 Hz
Operating Temperature-25°C to 60°C
Warranty5 years
Output Voltage120/240VAC
CommunicationRS485
CoolingFan
Weight77 lbs (35 kg)
Dimensions670 x 530 x 220 mm