7.2
Application Settings
EPS Voltage Set(V): Set voltage of the inverter’s output.
PV Grid Off: If the customer wants the system to have Off-Grid functionality without in-
stalling any batteries, please enable PV Grid Off. Please note, in this situation the Off-Grid en-
ergy is supplied by solar and is not stable. We suggest the customer install battery/batteries to
keep the EPS/UPS output voltage stable if they want to have Off-Grid function. (Allow system
to access the Off-Grid mode when only solar input is available)
Power Backup: If Power Backup function is Enabled, the LOAD terminal will maintain output
when AC is interrupted. You can set “Power Backup” via web or “Off-Grid Output” by LCD.
(When enabling this mode, the inverter’s output will be uninterrupted).
Seamless EPS Switching: When power is interrupted, the inverter will turn to EPS mode
seamlessly unless there is a grid voltage fluctuation issue; in which case, we suggest you set to
“Disableto avoid misjudgment.
Grid Sell Back: In some cases, the customer cannot feed energy into grid. If the customer
does not want to feed energy to grid, you can disable the Grid Sell Back function.
Grid Sell Back Power(kW): If Grid Sell Back function is enabled, you can adjust the power
limitation to feed into the grid.
Fast Zero Export: Normally the inverter will adjust output power every 5 seconds to avoid
export. If Fast Zero Export is enabled, the inverter will adjust output power accordingly.
Max. AC Input Power(kW): The inverter can adjust the charge power based on the detected
inverter’s load consumption and max. AC Input power limitation.
PV Arc: Only available for the US model. The inverter will detect when there is a PV input
Arc Fault and protect the inverter from an Arc Fault.
PV Arc Fault Clear: Clear the records of PV Arc fault.
Run Without Grid: Enable for Off-Grid operations.
RSD: The rapid shut-down detection of the PV inputs.
Normal/Standby: “Standby” is used to set the system into standby mode, stopping feed in,
charge and discharge. “Normal” is used to set the whole system to auto run status.
Restart Inverter

Table of Contents

Other manuals for EG4 18KPV

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EG4 18KPV and is the answer not in the manual?

EG4 18KPV Specifications

General IconGeneral
ModelEG4 18KPV
CategoryInverter
Rated Power18 kW
Max. AC Output Current75A
Surge Power36 kW
Number of MPPTs2
Frequency50/60 Hz
Operating Temperature-25°C to 60°C
Warranty5 years
Output Voltage120/240VAC
CommunicationRS485
CoolingFan
Weight77 lbs (35 kg)