EasyManuals Logo

EG4 18KPV User Manual

EG4 18KPV
95 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #59 background imageLoading...
Page #59 background image
59
4. Select the Wi-Fi network you want to connect to and the click “OK. Input the Wi-Fi password
and click “Save.”
5. After saving your settings, the dongle will restart. After you set the password, three lights will be
solid on, which means the inverter is connected to the server. You can now input your account
login and password to begin monitoring your system.
8.3.2 Dashboard (Monitor Tab)
Once your account is created, log in and you will be brought to the main page (Monitor tab) of the monitor-
ing interface.
Name
Description
Select station first
Select which station to view, and then select which unit/dongle to view by choosing a serial
number from the dropdown list. Note: Unchecking the box will only display serial numbers
linked to the account.
Solar Yielding
Shows power generated by the solar panels (for AC coupled inverters it shows the power
generated by the on-grid inverter). The PV CT clamp will have to be installed to be able to
show the data correctly. When the picture of the solar yielding is clicked, it will display how
the solar energy has been used that day. A second click will show the totals since
commissioning.
Battery Dis-
charging/Charging
Shows the charge and discharge energy from the battery/batteries. When the battery picture
is clicked, the display will switch between battery discharging and battery charging, showing
totals for that day and since commissioning.
Feed-in En-
ergy/Import
Shows energy exported to grid for that day and since commissioning. When the picture is
clicked, it shows energy imported from the grid for that day and since commissioning.
Consumption
Shows the total energy consumption of the property for that day and since commissioning.
System information
Displays power sources and energy flow, voltage, and amperage from lines to loads. Clicking
the button beside the status will refresh the information to reflect real time data.
Note: When the battery’s color is yellow or red it means there is a warning or fault with the
battery.
Start Quick Charge
Clicking this will direct the inverter to charge batteries faster for one hour. It will then default
back to its original setting.

Table of Contents

Other manuals for EG4 18KPV

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EG4 18KPV and is the answer not in the manual?

EG4 18KPV Specifications

General IconGeneral
ModelEG4 18KPV
CategoryInverter
Rated Power18 kW
Max. AC Output Current75A
Surge Power36 kW
Number of MPPTs2
Frequency50/60 Hz
Operating Temperature-25°C to 60°C
Warranty5 years
Output Voltage120/240VAC
CommunicationRS485
CoolingFan
Weight77 lbs (35 kg)
Dimensions670 x 530 x 220 mm