DL8000 Preset Instruction Manual
Revised February-2016 DL8000 Keypad Display E-69
Loaded:
250
Gal
Corrected: 60 deg F
Temp: 25
Vol Units: Gal
Gross: 250
Net: 248
If the batch stops (“halts”) during loading due either to user intervention
or an alarm halt, one of the following screens displays:
Loaded:
899
Gal
Corrected: 60 deg F
Temp: 25
Vol Units: Gal
Gross: 899
Net: 890
Loaded:
899
Gal
Corrected: 60 deg F
Temp: 25
Vol Units: Gal
Gross: 899
Net: 890
Note: If an alarm occurs during a prover batch, you must reset the
alarm. Until you resolve the alarm condition, you cannot use the
keypad to switch to program mode.
Loading Mode to
Program Mode
When batch loading completes successfully, the system automatically
shifts to program mode [63,0,9].
If an alarm halt or a user-initiated halt (from pressing STOP) occurs
during loading, once the batch ends the system automatically enters
program mode.
At the initiation of program mode the system checks for the following
conditions to ensure the batch is valid for proving:
SL. No.
Condition to check
valid batch
Action taken
1
Any flow alarm or
fallback alarm during
batch loading (see
note below)
Warning displays before you enter a
prover volume.
If you press ENTER, the system displays
a screen on which you enter the prover