EasyManua.ls Logo

Emerson DSM314 - Page 509

Emerson DSM314
519 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual Appendix H
GFK-1742F Jan 2020
Using VersaPro with the DSM314 498
After completing the program entry, the resulting VersaPro screen should look similar to
the figure shown below (Figure 261).
Figure 261: CAM Example VersaPro Screens
Step 10: Set up Hardware Configuration in VersaPro
Change the following Settings tab parameters to the values shown. (Axis 1 and Axis 2 modes
are set to digital servo because this example uses the
is 0.5 digital servo.)
Axis 1 Mode
Digital Servo
Axis 2 Mode
Digital Servo
Local Logic Block Name
CamExLLPgm
Cam Block Name
CamBlk
Local Logic Mode
Enabled
Note: This example uses only one DSM314.The DSM314 executes the files (CAM, Local Logic, and Motion
Program) pointed to by the configuration. Multiple DSM314 modules can run the same Local
Logic program, motion programs, or CAM Blocks. This allows you to have one source file for
multiple DSM314 modules. Note that this does not prevent DSM314s from executing different
programs.
The resulting Settings tab will be as shown in Figure 262.