Proline Promag W 800 Technical data
Endress+Hauser 99
Maximum input values DC 30 V
30 mA
Voltage drop At 25 mA: ≤ DC 2 V
Pulse output
Pulse width Configurable: 0.1 to 500 ms
Maximum pulse rate 100 Impulse/s
Pulse value Configurable
Assignable measured
variables
Volume flow
Switch output
Switching behavior Binary, conductive or non-conductive
Switching delay Configurable: 0 to 100 s
Number of switching
cycles
Unlimited
Assignable functions Off
On
Diagnostic behavior
Limit value:
Off
VolumeFlow
FlowVelocity
Conductivity
Totalizer 1
Totalizer 2
Totalizer 3
Temperature
Pressure
BatteryLevel
Flow direction monitoring
Status
Empty pipe detection
Low flow cut off
Status output, power save mode
An active status output is not permanently conductive. Rather, it is only
conductive for the length of the pulse width at a repeat rate that corresponds to
the device measurement interval.
Signal on alarm Depending on the interface, failure information is displayed as follows.
Status/pulse output
Status/pulse output
Failure mode No pulses
Local display
Plain text display With information on the cause
Interface/protocol
Via digital communication:
SmartBlue App
Plain text display With information on cause and remedial measures