Proline Promag W 800 Technical data
Endress+Hauser 119
• CAN/CSA-C22.2 No. 61010-1-12
Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory
Use - Part 1 General Requirements
• ETSI EN 300 328
Guidelines for 2.4 GHz radio components.
• EN 301489
Electromagnetic compatibility and radio spectrum matters (ERM).
16.13 Application packages
Many different application packages are available to enhance the functionality of the
device. Such packages might be needed to address safety aspects or specific application
requirements.
The application packages can be ordered with the device or subsequently from
Endress+Hauser. Detailed information on the order code in question is available from your
local Endress+Hauser sales center or on the product page of the Endress+Hauser website:
www.endress.com.
Diagnostics functions Order code for "Application package", option EM "Extended data logger"
Comprises extended functions concerning the event log and the activation of the measured
value memory.
Event log:
Memory volume is extended from 10 000 message entries (standard version) to 50 000
entries.
For detailed information, see the Operating Instructions for the device.
Heartbeat Technology Order code for "Application package", option EB "Heartbeat Verification + Monitoring"
Heartbeat Verification
Meets the requirement for traceable verification to DIN ISO 9001:2008 Chapter 7.6 a)
"Control of monitoring and measuring equipment".
• Functional testing in the installed state.
• Traceable verification results on request, including a report.
• Simple testing process via local operation or other operating interfaces.
• Clear measuring point assessment (pass/fail) with high test coverage within the
framework of manufacturer specifications.
• Extension of calibration intervals according to operator's risk assessment.
Heartbeat Monitoring
Continuously supplies data, which are characteristic of the measuring principle, to an
external condition monitoring system for the purpose of preventive maintenance or
process analysis. These data enable the operator to:
• Draw conclusions - using these data and other information - about the impact process
influences (e.g. buildup, interference from the magnetic field) have on the measuring
performance over time.
• Schedule servicing in time.
• Monitor the process or product quality .
For detailed information, see the Special Documentation for the device.
16.14 Accessories
Overview of accessories available to order → 94