L1800 Revision A
Disassembly And Assembly Disassembling the Printer Mechanism 67
Confidential
17. Lift the Carriage Shaft within the hole on the Main Frame, and remove the Spacer
and Left PG Cam from the Carriage Shaft.
Figure 3-71. Removing Left PG Cam
18. Remove the Spacer and Right PG Cam from the Carriage Shaft.
Figure 3-72. Removing Right PG Cam
19. Pull the Right CR Shaft Mounting Plate away from the tab on the Main Frame and
rotate toward you.
Figure 3-74. Rotating the Right CR Shaft Mounting Plate
Install the Right PG Cam so that one of these positions marked “0”,
“+” or “++” faces downward.
Figure 3-73. Right PG Cam Installation Direction
Right CR Shaft
Mounting Plate
Tabs