05-2019 0073 00 47
motor-DosEr calibratioN
The calibration of instant products and pre-
ground coee in the motor-dosers allows
the motor-doser operating speed to be ad-
justed and the ow rate to be dened in g/s.
To calibrate, proceed as follows:
1. Dispense the powder at the lowest
speed.
2. Weigh the dispensed instant powder.
3. Enter the measured weight.
4. Dispense the powder at maximum
speed.
5. Weigh the dispensed instant powder.
6. Enter the measured weight.
pump/solENoiD valvE calibratioN
The calibration allows the ow capacity to
be adjusted in cc/s.
To calibrate, proceed as follows:
1. Dispense the water at the minimum flow
rate.
2. Measure and enter the amount of dis-
pensed water.
3. Dispense the water at the maximum flow
rate.
4. Measure and enter the amount of dis-
pensed water.
Evomilk aDvaNcED sEttiNgs
The self-calibration can be performed
from the function; this allows the pa-
rameters to be optimally set.
Specic parameters of the Evomilk cappuc-
cino maker can be customised, such as the
thresholds, amount of water used to rinse
the nozzle, milk circuit lling time, etc.
After the parameters have been changed, it
is important to check that the new settings
work correctly.
output sEttiNgs
brEwiNg
uNit
-No coffee: a sensor detects the rotation of
the grinder when it is grinding; if a block
(e.g. foreign bodies) or excessive speed
(grinder empty) occurs, the control blocks
the selections which use the grinder.
-Pregrinding: enables/disables the coffee
grinder for the next selection. Pregrinding
reduces the preparation time of the next
selection containing ground coffee.
Pregrinding affects the aroma of the next
selection containing ground coffee.
-“Use decaffeinated coffee” option: allows
the “use decaeinated coee” option to be
enabled for a selection that uses coee
(beans and/or pre-ground).
-Allows the position of the brewing unit's
infusion chamber to be set.
Set the infusion chamber’s position to
allow the coffee powder to be arranged
more evenly in the infusion chamber.
-Enable/disable the brewing unit heating
when it is not used for a certain amount of
time.
faN paramEtErs
Enables/disables the operation of the appli-
ance's fans.
stEam suctioN
-ON: the fan is always active.
-OFF: the fan is active whilst the beverage
is being prepared.
The fan stays on until the dispensing is
complete and for the time that has been
set.
ligHtiNg
Allows the appliance's lighting parameters
to be set.