HEatiNg uNit paramEtErs
Sets the operating parameters of the heat-
ing unit(s).
-Temperature: sets the operating tempera-
ture of the heating unit.
-Minimum temperature for dispensing bev-
erages: sets the minimum temperature for
making beverages available.
If the heating unit temperature is lower
than the temperature that has been set, a
“low temperature” error message will be
displayed.
With the "Temperature threshold" and "Min-
utes” parameters, the heating unit’s heating
cycle can be set to compensate for the rst
espresso’s low temperature.
For example, if no beverages are dis-
pensed during the set minutes, the tem-
perature of the water in the heating unit is
increased by the degrees set in the "Tem-
perature threshold".
A higher temperature value can be set so
that the “low temperature” message will not
be displayed.
mixEr aNti-lock
Sets how long after the last instant selec-
tion to briey activate the mixers (anti-lock
function).
The function is useful if instant powder resi-
dues remain in the mixers.
motorisED aDjustmENt of tHE burrs
The grain size (coarser or ner) can be ad-
justed on appliances with a motorised burr
adjustment device.
Set the value (expressed in 1/6 of a turn of
the burr-holding locking ring) to move the
burrs closer or farther away.
When the burrs are moved closer together,
a ner grain size is obtained.
When the burrs are moved farther away, a
coarser grain size is obtained.
Alternatively, manually turn the grinder
adjustment knob on machines without a
motorised burr adjustment device.
NExt maiNtENaNcE
Enable and set the number of days and/or
the number of dispenses.
When one of the values that has set is
reached, the appliance will display a “per-
form maintenance” message.
maiNtENaNcE NotificatioN
Reset the counter that manages the main-
tenance alerts.
In order to correctly manage the noti-


been carried out.
NExt watEr softENEr maiNtENaNcE
Enable and set the number of litres at
which a “perform maintenance” message is
displayed, regarding the softener.
softENEr maiNtENaNcE NotificatioN
Reset the counter that manages the soften-
er warnings.
In order to correctly manage the noti-


been carried out.