Test Setup - Test Configurator, Timer, and System
MaxTester 113
Interface
For EtherBERT test application:
Remote Fault Emulation check box when selected, generates Remote
Fault ordered sets when a Link Fault is received. Only available with
EtherBERT on 890 and 890Q models, 10GE (all framing at the exception
of Seed A/B and PRBS31 Unscrambled), and 40GE/100GE (Framed
Layer 2 and up.
For Ethernet test application:
For optical interfaces, the Local Fault Detected, Local Fault Received,
Remote Fault, LOA, Hi-BER,and/or WIS Link (10GE WAN) alarm
status are displayed. Refer to Ethernet on page 216 and Ethernet - PCS
Lanes on page 220 for more information.
Auto-Negotiation check box is available with 10/100/1000M Electrical
and 1GE Optical interfaces. When the Auto-Negotiation check box is
selected the test application indicates to the remote port which
parameters to use. The Auto-Negotiation check box is automatically
selected (not configurable) for 1GE Electrical interface and when using
an active copper SFP.
Note: When the Auto-Negotiation check box is selected, the port Speed, Duplex,
Flow Control, and Local Clock parameters can be set. Those settings are
not applied immediately to the port, they are used only when the
negotiation process is started and take effect only when the
auto-negotiation succeeds. However current settings are applied
immediately to the port when the Auto-Negotiation check box is cleared.