Test Setup - Test Configurator, Timer, and System
144 MAX-800 Series
RFC 2544 - Subtests
Accuracy is the accuracy measurement in percentage of the line rate
(%), Mbit/s, or in Gbit/s. The accuracy is not based on the configured
Maximum Rate but on the Ethernet line rate:
Note: For Dual Test Set using different rates on local and remote, the accuracy on
the remote will be set using the same percentage of its line rate as the local.
For example, if the local interface is 1GE with an accuracy of 0.1 Gbit/s
which correspond to an accuracy of 10% and the remote interface is 10GE,
the 10% is applied to its line rate corresponding to an accuracy of 1 Gbit/s.
Acceptable Errors represents the number of acceptable errors for the
test: 0 (default) to 10.
Validations represents the number of times the result should be
validated: 1 (default) to 50 times.
Interface
Speed
Max. Rate
% Mbit/s Gbit/s
10 Mbit/s 0.01 to 10.0 (default 1.0) 0.01 to 1.0 (default 0.10) Not Applicable
100 Mbit/s 0.01 to 10.0 (default 1.0) 0.1 to 10.0 (default 1.0) Not Applicable
1000 Mbit/s 0.01 to 10.0 (default 1.0) 1 to 100.0 (default 10) 0.001 to 0.100 (default 0.010)
10G LAN 0.01 to 10.0 (default 1.0) 10.0 to 1000.0 (default 100) 0.01 to 1.00 (default 0.10)
10G WAN 0.01 to 10.0 (default 1.0) 10.0 to 1000.0 (default 100.00) 0.01 to 1.00 (default 0.1)
100G 0.01 to 10.0 (default 1.0) 100.0 to 10000.0 (default 1000.0) 0.10 to 10.00 (default 1.0000)