Test Setup - Test Configurator, Timer, and System
MaxTester 91
Clock
LBO (Line Build Out), available with DS1 only, allows the selection of
the interface Line Build Out that meets the interface requirements over
the full range of cable lengths: DSX-1 (0-133 ft) (default),
DSX-1 (133-266 ft), DSX-1 (266-399 ft), DSX-1 (399-533 ft), and
DSX-1 (533-655 ft).
Line Coding, available with DS1 and E1, allows the selection of the
interface line coding.
For DS1: AMI and B8ZS (default).
For E1: AMI and HDB3 (default).
Framing, available with DS1 and E1, allows the selection of the
interface framing.
For DS1: SF, SLC-96, and ESF (default).
For E1: PCM30 (default), PCM30 CRC-4, PCM31, and PCM31 CRC-4.