DTP CrossPoint 4K Series Matrix Switchers • Matrix Software 122
Viewing and using a group master
Click View > Group Controls to open the Group Controls dialog box (see figure 65).
Figure 65. Group Controls Dialog Box
• Slide a group fader up and down to adjust all gain controls in the group.
• Click and drag a soft limit ( ) to set the upper or lower volume limits for the group.
NOTES:
• The soft limits cannot be dragged beyond the current setting of the group fader;
the upper limit cannot be set below the fader and the lower limit cannot be set
above the fader.
• None of the individual gain faders can be dragged below the lower limit or
above the upper limit of the soft limits of the group.
• Click the Mute button in a mute group to mute or unmute all blocks in the group.
NOTES:
• If a block is muted, that block remains muted when the group mute is released.
• Unmuting a group master does not unmute a member that is individually muted.
• Click Add a Group on the Group Controls dialog box menu bar to open the Configure
Groups dialog box (see Configuring a group master and figure 64 on page 120).
• Click Tools > Clear All Groups in the Group Controls dialog box to delete all groups.
• Click Tools > Increment/Decrement Simulator in the Group Controls dialog box to
open a dialog box (see figure 66) that lets you easily experiment with fine adjustments.
Figure 66. Increment/Decrement Simulator Dialog Box
NOTES:
• You must select a group before the other controls in the dialog box are active.
• The size of the increment can be changed from its default value of 1 dB by typing
a value in the
Increment Value or Decrement Value field, to as fine as 0.1 dB.