DTP CrossPoint 4K Series Matrix Switchers • Matrix Software 91
2. If necessary, click the Logos tab to open the logos controls (see figure 47 on the
previous page,
2
).
3. Click the desired logo in the Logo Management column (
3
).
4. Click the desired Logo Assigned to: output check box to toggle the logo assigned
and unassigned.
Configuring RS-232 Insertion Parameters
Set RS-232 insertion parameters for one or more TP inputs and outputs (see below) as
follows:
Matrix size Inputs Outputs
10x8 7 through 10 5 through 8
8x6 and 8x4 7 and 8 3 and 4
8x2 7 and 8 1 and 2
1. Click the General Settings tab (see figure 48,
1
). The General Settings page
displays.
1111111111
22
22222222
33
33333333
Figure 48. General Settings Panel, DTP CrossPoint 108 4K Shown
2. Double-click the port to be configured (
2
) or click the Gear icon ( ). The Configure
Port dialog box opens (see figure 49 on the next page).