DTP CrossPoint 4K Series Matrix Switchers • HTML Pages 155
The input status panel displays the connection status of each input. The output status panel
displays the selected resolution of scaled outputs. The various lock icons have the following
meanings:
Input Status locked ( ) — The input is HDCP compliant.
Input Status unlocked ( ) — The input is not HDCP compliant.
Output Status locked-check ( ) — The connected display is HDCP compliant and
an encrypted signal is routed to it.
Output Status locked-X ( ) — The connected display is HDCP compliant but currently
not encrypted.
Change the Communications Settings
Click the Edit button in the Communications Settings panel (see figure 84,
1
) to open
the Communications Settings dialog box. The dialog box provides a location for viewing
and editing settings unique to the Ethernet interface. See the IPCP Pro Series User Guide at
www.extron.com for basic information about IP addresses.
1111111111
22
22222222
33
33333333
44
44444444
55
55555555
77
77777777
77
77777777
66
66666666
Figure 84. Communications Settings Dialog Box
Address Fields (DHCP Not Selected)
The IP Address field (
2
) contains the IP address of the connected matrix switcher. This
value is encoded in the flash memory in the switcher.
The Subnet Mask field (
3
) is used to determine whether the matrix switcher is on the same
subnet as the controlling PC when you are subnetting.
The Default Gateway field (
4
) identifies the address of the gateway to the controlling PC
to be used if the matrix switcher and the mail server are not on the same subnet.