DTP CrossPoint 4K Series Matrix Switchers • Matrix Software 131
Firmware Loader — Calls the Firmware Loader program, which allows you to replace
the switcher firmware without taking the switcher out of service. This is similar to the Product
Configuration Software Update Firmware selection (see Updating the Firmware on page 93).
Organize Building Blocks — Opens the Organize Building Blocks dialog box,
in which you can save building blocks, move them within folders, or delete them (see
Organizing listed building blocks on page 140).
Configure Groups — Opens the Configure Groups dialog box (see Configuring a
group master on page 120).
Device Setting — Opens a dialog box that provides a means to set the IP address and
passwords of the unit and to set the baud rate for the serial port.
Options — Opens a tabbed dialog box that allows you to tailor the appearance and
operation of the DSP Configurator program to your liking:
Appearance — Change the color style of the program.
Complimentary Colors — Set the primary and secondary colors in the filter blocks.
Complimentary colors allows custom selection of colors used with the various graphs
and dialog boxes. Graph colors change the row colors containing the information and
descriptions of the graphs seen in the processor blocks.
Graph Colors — Change the row colors containing the information and descriptions
of the graphs seen in the processor blocks.
Preferences — Contains options for selection of the devices to connect to, or to
Always ask on startup. That selection can be changed using Default Device.
If Show Meters is set to True, Dynamic Block Meters can be used to tailor the
appearance of the dynamics meters to use the full meter to show input and gain
reduction, or to show the level based on the output and gain reduction.
Processor Defaults — Sets the default parameters for all processors. Also allows
you to restore the factory defaults for these processors.
DSP Configurator Window menu
Cascade — Rearranges all open DSP Configurator program windows,
including dialog boxes, in a cascading array.
Close All Windows — Closes all open dialog boxes.
Individual windows — Brings the associated dialog box to the front of the desktop.
DSP Configurator Help selection
Help > Contents opens the DSP Configurator program Help file.
DSP Configurator Presets drop-down menu
Displays a list of up to 32 presets, which can include
ties and audio settings. You can select a preset from
the list to display it in the window and either activate it
(Recall), abort the selection without either recalling or
deleting it (Cancel), or delete it (Delete) (see Recall a preset on page 125).
NOTES:
The Recall, Cancel, and Delete buttons appear when a preset is selected.
An asterisk (*) in the drop-down menu indicates that a preset that only exists in
the switcher has not been saved to the configuration file of the DSP Configurator.
The ties and settings of the preset are not in sync between the DSP Configurator
program and the switcher.