IN1806 and IN1808 Series Scaling Presentation Switchers • SIS Configuration and Control 61
X7@
= Key effect
0 = Disabled (default)
1 = Transparency
2 = RGB key
3 = Level key
4 = Alpha key
X8)
= Audio playback file slot number
1 through 16
Highest priority for playback is slot 1, descending to
lowest priority slot 16.
X8@
= Playback state
0 = Stop or stopped
1 = Play or playing
X8#
= Repeat
0 = No
1 = Yes
NOTE: Setting the repeat mode to 0 during
continuous playback causes play to stop after the
end of the current iteration.
X8$
= Playback delay Number of seconds to wait before the audio file repeats
(valid only if
X8#
= 1 [repeat]).
1 through 300 (1-300 seconds delay between audio
playbacks)
0 = No delay
X8%
= Configuration type
0 = IP configuration (ip.cfg)
2 = Unit-specific parameters (box.cfg)
X8^
= Number of open connections
0-<maximum number of open connections>
X8&
= IP address
Format nnn.nnn.nnn.nnn
Default = 192.168.254.254
Leading zeros in each of the four octets are optional in
setting values, and are suppressed in returned values.
X8*
= Gateway IP address
Format nnn.nnn.nnn.nnn
Default = 0.0.0.0
Leading zeros in each of the four octets are optional in
setting values, and are suppressed in returned values.
X8(
= Subnet mask
Format nnn.nnn.nnn.nnn
Default = 255.255.255.0
Leading zeros in each of the four octets are optional in
setting values, and are suppressed in returned values.
X9)
= Hardware (MAC) address
00-05-A6-xx-xx-xx
X9!
= Password Length is 1-128 characters.
All human-readable characters are allowed except
|
.
The password cannot be a single space.
Passwords are case-sensitive.
A user password cannot be assigned if no
administrator password exists. An E14 error code is
returned.
If the admin password is cleared, the user password
is cleared as well.
X9@
= Default unit name Combination of the model name and the last three
hexadecimal character pairs of the unit MAC address
(Example: IN1808-IPCP-SA-15-9E-B0)
X9#
= Subnet mask in CISG
commands
Prefix representing subnet mask bits (subnet mask value
in CISG commands).
Default = /24, which represents the default subnet mask,
255.255.255.0.