IN1806 and IN1808 Series Scaling Presentation Switchers • SIS Configuration and Control 87
Group Master SIS Command and Response Table
Command ASCII Command
(Host to Scaler)
Response
(Scaler to Host)
Additional Description
Audio Group Master
View Group Master
View soft limits
E
L
X10!
GRPM
} X10#
*
X10$]
In verbose modes 2 and 3:
GrpmL
X10!
*
X10#
*
X10$]
View low soft limit
X10$
and high soft
limit
X10#
for group
X10!
.
Group Master Value
Set a group fader value
E
D
X10!
*
X10%
GRPM
}
GrpmD
X10!
*
X10%]
Set the level of group fader
X10!
to
X10%
.
Example:
E
D3*-293GRPM
}
GrpmD3*-293
]
Set group 3 fader control to -29.3 dB.
View group fader value
E
D
X10!
GRPM
} X10&]
In verbose modes 2 and 3:
GrpmD
X10!
*
X10&]
View the group fader value.
Increment a group fader
value
E
D
X10!
*
X10^
+GRPM
}
GrpmD
X10!
*
X10%]
Increase the gain value of group
X10!
by
X10^
to
X10%
.
Example:
E
D3*30+GRPM
}
GrpmD3*-263
]
Raise the group 3 fader by 3 dB
from -29.3 dB (set in the previous
example) to -26.3 dB.
Decrement a group fader
value
E
D
X10!
*
X10^
–GRPM
}
GrpmD
X10!
*
X10%]
Decrease the gain value of group
X10!
by
X10^
to
X10%
.
Mute a group
E
D
X10!
*1GRPM
}
GrpmD
X10!
*1
]
Mute all blocks in group
X10!
.
Unmute a group
E
D
X10!
*0GRPM
}
GrpmD
X10!
*0
]
Unmute all blocks in group
X10!
.
View group mute status
E
D
X10!
GRPM
} X10&]
In verbose modes 2 and 3:
GrpmD
X10!
*
X10&]
View the group master mute status.
KEY:
X10)
= Object ID (OID) number
See the Object Identification number table on page 85.
X10!
= Group master group number
1 through 10.
Preconfigured group. Can alternatively be an alias, which is the
user-defined group name enclosed in braces ({ }).
X10#
= Soft limit high value in dB The valid range for
X10#
must be within the range for the gain block
grouped in
X10!
.
X10$
= Soft limit low value in dB The valid range for
X10$
must be within the range for the gain block
grouped in
X10!
.
X10%
= Group master value
Value in 0.1 dB steps. For gain value with a resolution to 0.1, multiply
by 10. For mute values, use 0 or 1.
Example: -100.0 dB through +80.0 dB is represented by -1000
through 800. The valid range depends on the type of gain block
assigned to the group number (
X10!
).
X10^
= Increment or decrement value
Value in 0.1 dB steps. For gain value with a resolution to 0.1, multiply
by 10. For mute values, use 0 or 1 as the value.
X10&
= Group master mute status
0 = unmuted, 1 = muted