Chapter 6 Fastening Operation
PAGE 6-68
Rate
D-No. 300 Rate 1 Low Limit [N
・
m/deg]
Setting range: - maximum torque rate of tool ~ maximum torque rate of tool
Sets the low limit value of Rate 1 (slope of torque vs. angle) between the two points of D-No. 112
[Rate 1 Start Torque] ~ D-No. 113 [Rate 1 End Torque]. A judgment is made at the point at which
D-No. 113 [Rate 1 End Torque] is attained.
D-No. 301 Rate 1 High Limit [N
・
m/deg]
Setting range: - maximum torque rate of tool ~ maximum torque rate of tool
Sets the high limit value of Rate 1 (slope of torque vs. angle) between the two points of D-No. 112
[Rate 1 Start Torque] ~ D-No. 113 [Rate 1 End Torque]. A judgment is made at the point at which
D-No. 113 [Rate 1 End Torque] is attained.
D-No. 302 Rate 2 Low Limit [N
・
m/deg]
Setting range: - maximum torque rate of tool ~ maximum torque rate of tool
Sets the low limit value of Rate 2 (slope of torque vs. angle) between the two points of D-No. 114
[Rate 2 Start Torque] ~ D-No. 115 [Rate 2 End Torque]. A judgment is made at the point at which
D-No. 115 [Rate 2 End Torque] is attained.
D-No. 303 Rate 2 High Limit [N
・
m/deg]
Setting range: - maximum torque rate of tool ~ maximum torque rate of tool
Sets the high limit value of Rate 2 (slope of torque vs. angle) between the two points of D-No. 114
[Rate 2 Start Torque] ~ D-No. 115 [Rate 2 End Torque]. A judgment is made at the point at which
D-No. 115 [Rate 2 End Torque] is attained.
D-No. 304 Rate 3 Low Limit [N
・
m/deg]
Setting range: - maximum torque rate of tool ~ maximum torque rate of tool
Sets the low limit value of Rate 3 (slope of torque vs. angle) between the two points of D-No. 116
[Rate 3 Start Torque] ~ D-No. 117 [Rate 3 End Torque]. A judgment is made at the point at which
D-No. 117 [Rate 3 End Torque] is attained.
D-No. 305 Rate 3 High Limit [N
・
m/deg]
Setting range: - maximum torque rate of tool ~ maximum torque rate of tool
Sets the high limit value of Rate 3 (slope of torque vs. angle) between the two points of D-No. 116
[Rate 3 Start Torque] ~ D-No. 117 [Rate 3 End Torque]. A judgment is made at the point at which
D-No. 117 [Rate 3 End Torque] is attained.
* To input a negative value for any of D-No. 300 ~ D-No. 305, move the cursor (flashing number) at
the DATA Display to the position of “P” and then press the “▲” or “▼” button to make “-“ be
indicated at the cursor position.