Chapter 6 Fastening Operation
PAGE 6-21
6-4 Parameter Copy / Erasing the Fastening Result History / Formatting of the CF Card
NOTE: Copying parameters is performed easier using the HFC3000 Software – this is provided in the
case software is not available
When multiple parameter sets need to be changed, one parameter can be copied to another parameter
while in the parameter edit mode.
Use the following procedure to copy parameters;
1. Operate the arrow pushbuttons to display “Copy,” with “SYS” indicated in the PAR No. display and
“022” indicated in the D-No. display.
2. Press and hold the PROG button of the Controller until the “022” blinks. Then press the [SET]
pushbutton and the COPY source/destination parameter numbers will appear in the upper
display.
3. Select the copy source parameter No. in the first 2 digits of the upper stage of the display (DATA).
4. Select the copy destination parameter No. in the last 2 digits of the upper stage of the display
(DATA).
5. Press the [SET] pushbutton, press the [▲] or [▼] pushbuttons to change the indication from
“Copy NO” to “Copy YES” within 2 seconds, and then press the [SET] pushbutton again within 2
seconds.
6. Copying one parameter to another parameter is complete.
7. Press and hold the PROG button of the Controller until the "022" stops blink.
●Batch Copying
Ex.:Copy parameter 1 to parameter 2~32
1. Operate the arrow pushbuttons to make “Copy,” with “SYS” indicated in the PAR No. display and
“022” indicated in the D-No. display.
2. Press and hold the PROG button of the Controller until the “022” blinks. Then press the [SET]
pushbutton and the COPY source/destination parameter numbers will appear in the upper
display.
3. Select the copy source parameter No. in the first 2 digits of the upper area of the display (DATA).
4. Select “99” in the last 2 digits of the upper area of the display (DATA) and then press the [SET]
pushbutton.
5. Press the [▲] or [▼] pushbuttons to change the indication from “Copy NO” to “Copy YES” within 2
seconds, and then press the [SET] pushbutton within 2 seconds.
6. Parameter 1 will be copied to parameter 2~32.
7. Press and hold the PROG button of the Controller until the "022" stops blinking.