Chapter 4 Installation and Wiring
PAGE 4-7
4-5 External Control Signal Connection
Digital Input / Output (DIO) Terminal Block: TB1,2,3
TB3 12
TB3: 12 terminals
*The No. 11 terminal at the plug side
lacks a alignment pin. (See below)
TB3 1
TB2 12 TB2: 12 terminals
TB1: 12 terminals
TB2 1 *The No. 1 terminal at the plug side lacks a
Alignment pin.(see below)
TB1 12
TB1 1
Mating Connector Model: SL-4000CP-12PGY
Manufacturer: SATO PARTS
Rated applicable wire: Solid wire 0.8mm φ (AWG 20), stranded wire 0.5mm
2
(AWG 20)
Range of useable wires: Solid wire 0.4mm φ ~ 1.2mm φ (AWG 26 ~ AWG 16)
Stranded wire 0.2mm
2
to 1.25mm
2
(AWG 24 ~ AWG 16)
Wire outer diameter 0.18mm φ or more
Standard wire stripping length: 9mm (0.35”)
Note: One wire is connected to one terminal. Do not connect two or more wires to one terminal.
The No. 1 TB1 plug does not have an alignment pin.
The No. 11 TB3 plug does not have an alignment pin.
Wire insertion hole
Wire insertion releasing
lever
Checking hole
Top View