Chapter 9 Fieldbus I/O Interfaces
PAGE 9-24
Below are the properties which must be setup for the Message Configuration of the Write_Tag.
(Right Click in MSG command)
Message Type CIP Generic
Service Type Get Attribute Single
Service Code 10
Class A2
Instance 1
Attribute 5
Destination The controller tag VIN_Numberor whatever Write Tag you setup should be selected
Note: The FEC HFC Controller will only take a maximum of 32 Bytes for the Write_Tag (Part ID data) configurable
(between 0-32 bytes) in the HFC3000 software for the Fieldbus Message Setup. So an instance of 1 is all that is
required in the above setup for WRITING data using the Message Command.