Chapter 4 Installation and Wiring
PAGE 4-24
When the fastening judgment is NG (REJECT)
1 2 3 4 5 6 7 8 9 10 11 12 13 14
(JDG: Judgment, OCR: Occurrence)
[PEAK TORQUE] JUDGMENT
"H"(48H): HIGH REJECT "L"(4CH): LOW REJECT
"A"(41H): ABNORMAL "S"(53H): STOP
"B"(42H): BYPASS “R”(52H): RESET
“D” (44H): START OFF (Start trigger was released during fastening)
The OCR will identify the cause of the initial reject item and is not set in the
case of Judgments of "A," "B," "S," “R,” or “D.” above (see REJECT fastening
judgment output data example)
[FINAL TORQUE], [ANGLE], [RATE], [TIME] JUDGMENT
"H"(48H): HIGH REJECT "L"(4CH): LOW REJECT