3 Mounting and installation
82 Festo – P.BE-MPA-EN – 1309f – English
Example of address assignment (top view):
2
15 14
17
0
1
3
4
5
6
789
10
11 12
13
16
12 3 4 5
15
3
1
4
2
1
67
aJ
9
8
1 Addresses of solenoid coils 14 (manual
override 14)
2 Addresses of solenoid coils 12 (manual
override 12 )
3 LED for solenoid coil 12
4 LED for solenoid coil 14
5 Unused valve position
6 Sub-base with electronics module
VMPA2-MPM-EMM-4 occupies two
addresses per valve position
7 Supply plate for additional compressed air
supply
8 Sub-base with electronics mo dule
VMPA1-MPM-EMM-4 occupies one address
per valve position
9 Sub-base with electronics mo dule
VMPA2-MPM-EMM-2 occupies one address
per valve position
aJ
Sub-base with electronics mo dule
VMPA1-MPM-EMM-8 occupies two ad-
dresses per v alve position
Fig. 3.17 Example: address assignment of the MPA-S valve terminal w ith multi-pin plug connection
and 12 valve positions, type MPA-MPM-… (top view)