FT-70 Fill Level Inspector Service Manual
5-12
Function Descriptions
The following section contains function descriptions for each
function group. Depending upon your FT-70 machine type,
machine configuration, and options package, some of these
options may not apply to your FT-70.
Certain functions are available only while in the Calibrate Mode or
when dip switch S1-5 is open. To determine the availability of a
function refer to the Software Functions List.
Fill Level Functions Group
X-ray Status
This function activates or deactivates the X-ray Generator. When
the X-ray Status is off Error 123 displays and the warning beacon
flashes.
The X-ray Status is automatically disabled when the Safety
Interlock Switch is turned off. To turn the X-ray Status back on you
must:
1. Turn the Safety Interlock Switch on.
2. Press Key 1 until X-RAY STATUS appears.
3. Press the Arrow Key to turn the X-ray Source Status on. The
generator will take approximately 5 seconds to reach full
power and begin generating of x-rays.
Autoshutter Status
The Electronic Autoshutter is activated when the conveyor stops
for more than one-eighth second. When the autoshutter is
activated no inspection occurs and Error 123 displays.
The Electronic Autoshutter has two settings:
Auto: The shutter closes and opens automatically in accor-
dance with the conveyor motion.
Open: Forces the shutter to remain open for a maximum of
minutes. When 5 minutes is exceeded, the setting automati-
cally reverts to Auto.