Chapter 9: Using a PLC With Your FT-70
9-3
Using a PLC With Your FT-70
Programmable Logic Control (PLC) signals are provided by AC or
DC optically isolated solid-state Relays. The FT-70 has separate
PLC signals with a programmable pulse width (1-120 milli-
seconds) that transmits one pulse for each event. The signals are
available in the FT-70’s I/O Junction Box.
The FT-70 can report the following signals to a PLC:
• Sensor/X-ray Failure Alarm
• Latched Consecutive Alarms
• Rejector/Fill Level Status OFF
• Total Rejects
• Total Throughput
• Fill Level Rejects
• Bulged End Rejects
• Missing Lid Rejects
and the following Remote Alarms:
• Rejector/Fill Level Status OFF
• Fill Level Series Alarm
• Bulged End Series Alarm
• Missing Lid Series Alarm
• X-ray Failure Alarm
• Sensor Failure Alarm
Industrial Dynamics Company, Ltd. © Form 40256-0600