FT-70 Fill Level Inspector Service Manual
9-6
Relay Types for Output Signals
The FT-70 does not supply power to the PLC unit. The FT-70 signal
output is a solid-state relay that closes upon each event occurrence.
A resistor of the appropriate value may be needed across the load
attached to the relay. The resistor absorbs the 2 ma leakage and
meets the Minimum Current Load requirement. Refer to the
following illustrations for the resistor required for your specific
voltage.
Description Relay Type
Sensor/X-ray Failure Alarm Reed
Latched Consecutive Alarms Reed
Rejector/Fill Level Status Off Reed
Total Rejects Solid State
Total Throughput Solid State
Fill Level Rejects Solid State
Bulged End Rejects Solid State
Missing Lid Rejects Solid State