Chapter 5: System Software
5-29
6. After the new password is entered, the FT-70 takes a few
seconds to store the new password. When the change is
finished, the COMPLETED message appears.
7. Open dip switch S1-8. The Password Option is now activated.
You will be required to enter the password whenever you
attempt to enter the Calibrate Mode.
8. Press Key 5 until SYSTEM DISPLAY appears and then press
the Arrow Key to return to the Operate Mode.
9. Replace the FT-70’s cover.
View TB1 & TB4 Pin Assignments
Displays the signal wiring assignments for pins in Terminal Blocks
TB1and TB4. It also lists the normal voltage levels associate with
the signals.
To check which FT-70 inputs have been assigned to pins on
Terminal Block TB1 and TB4:
1. Press Key 5 until VIEW TB1 & 4 PIN ASSIGNMENTS appears.
2. Continue pressing the Arrow Key to scroll through the list.
The top line of the displays the sensor or function and its
assigned terminal pin.
The bottom line lists the voltage level and triggered action.
For example,
BLKD <1V, UNBLOCKED >17V means that if the
signal voltage is less than 1V, the trigger is blocked; and if
the signal is greater than 17V, the trigger is unblocked.
3. When you reach the end of the list the COMPLETED message
appears.
Industrial Dynamics Company, Ltd. © Form 40256-0600