5-38
PLC Series Alarms
Activates or deactivates the PLC Series Alarms Function. If set to
PRESENT, the following options are activated:
PLC Output Pulse Width
Alarm Series Underfills
Alarm Series Overfills
Alarm Series Missing Lid
Alarm Series Bulged End
Alarm Series Down Can
Alarm Series Dia. Missing Lid
Alarm Series Any Other Inspections.
PLC Assignments
See Chapter 9: Using a PLC With Your FT-70 for more information.
Serial Interface
Activates or deactivates the Serial Interface function. For more
information refer to the Serial Communication Manual.
External Trigger Logic
External Trigger Logic allows you to configure an external trigger,
such a s a manual switch, to perform either an External Reject or a
Remote Clear of Error.
External Reject: If the input TB1-20 is connected to ground (TB1-21)
the next container to pass the trigger will be rejected.
Remote Clear of Error: If the input TB1-20 is connected to ground
(TB1-21) the diagnostic error will be cleared.
Known Chain Pitch & Teeth
This option applies to the Encoder Calibration Routine. If you
know the conveyor chain pitch and the number of teeth per chain
link, set this function to present. If you do not know the conveyor
chain pitch and the number of teeth per chain link, set this function
to not present. When set to present you must also adjust the
Conveyor Segment Pitch and Teeth/Conveyor Segment options.
Industrial Dynamics Company, Ltd. © 40256-0600