EasyManua.ls Logo

Filtec FT-70c - Dip Switch Pack S2; S2-1: Baud Rate; S2-2: Handshake Flags; S2-3: Parity On;Off

Filtec FT-70c
243 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FT-70 Fill Level Inspector Service Manual
10-6
Dip Switch Pack S2
S2-1: Baud Rate
Defines the baud rate (bits per second) for the user serial port
(RS-422/423) as either 1200 or 9600. The default is 1200 baud.
S2-2: Handshake Flags
Enables the use of the Serial Hardware Handshake lines. The
default is off.
S2-3: Parity On/Off
Enables the parity bit in the Serial Data transmission. The default is
off.
S2-4: Parity Odd/Even
Allows selection of odd or even parity when S2-3 is open. The
default is odd.
S2-5: Character Size
Allows selection of 7 or 8 bit characters. The default is 8 bit.
S2-6: Multi-Serial
Enables the FT-70 for a multiple unit serial network and switches
the serial port from active open to tri-state, RS-485. The default is
RS-485.
S2-7: Led Section Selector
Defines current LED section. The default is section 1.
S2-8: Led Bank Selector
Defines current logical LED bank. The default is bank 1.
Industrial Dynamics Company, Ltd. © 40256-0600

Table of Contents

Related product manuals