FT-70 Fill Level Inspector Service Manual
8-18
X-ray System Troubleshooting
Testing the X-ray Generator
If the X-ray Generator is not generating, begin troubleshooting by
verifying the following:
1. Is the X-ray Source Function set to Present and the X-ray Status
Function turned on?
If the X-ray Source Function setting is Not Present, the
system will not know it is an X-ray enabled model and the
X-ray options will not be activated in the system software.
If the X-ray Status Function is turned off, Error 123 appears
and the beacon flashes to indicate that inspection can not
commence until the X-ray Generator is enabled.
2. Check the diagnostic LEDs on the X-ray Generator. Use the
following definitions and flow chart to interpret the LEDs.
The green LED indicates the generator is receiving the
proper 24 volts from the main power supply.
The red LED indicates that x-rays are being generated. The
red LED lights 20 seconds before the x-rays are emitted at
maximum strength.
The yellow LED indicates there is malfunction and the
generator should be replaced.