Chapter 5: System Software
5-13
Underfill Status
This function activates or deactivates the underfill inspection
capability of the FT-70. Deactivating this function inhibits
detection and rejection of containers with fill levels below the
underfill X-ray Threshold. Underfill and Overfill can not be active
simultaneously. To activate Underfill, you must close dip switch
S1-1.
Overfill Status
This function activates or deactivates the overfill inspection
capability of the FT-70. Deactivating this function inhibits
detection and rejection of containers with fill levels above the
overfill x-ray threshold. Overfill and Underfill can not be active
simultaneously. To activate Overfill, you must open dip switch
S1-1.
X-ray Counts
Displays the X-ray Count for the most recent container to pass
through the FT-70. The X-ray Count is the amount of radiation that
passes through the container and is captured by the radiation
sensor (Scintillation Tube or SSD). Each container’s x-ray count is
compared to the X-ray Threshold for that container type. If the
X-ray Count falls outside of the X-ray Threshold the container is
rejected.
Target Head Height
Allows you to record the Inspection Head height setting for the
current container configuration.
To record the Target Head Height:
1. Press Key 1 until you reach TARGET HEAD HEIGHT.
2. Read the value displayed in the Head Height Counter. The
counter is located in the upper left corner on the front of the
FT-70 (see illustration 4-2).
3. Use the Arrow Key to enter the value in the TARGET HEAD
HEIGHT function.