User Manual NTU Orion 2
107
Application of all configurations (Fault And Maintenance Management menu):
<APPLY ALL>
apply all configurations (written in the running configuration)
Confirmation of all configurations (Fault And Maintenance Management menu):
<CONFIRM>
confirm all configurations (written in the startup configuration)
7.1.2 Configuration of the FlexDSL Orion 2 device at the Customer Premises.
System configuration (Configuration Management menu):
<DEFAULT EVERYTHING>
enable default settings
Line interface configuration (Configuration Management menu):
<MASTER OFF>
enable the Slave mode
Configuration of the internal Ethernet switch (Network Management submenu):
<SETIP 10.0.2.201>
set the IP-address of the device (depends on the configuration
of the network)
<NETMASK 255.0.0.0>
set the subnet mask (this value is the same as in the connected
Ethernet network)
<GATEWAY 10.0.0.101>
– set the default gateway (this value is the same as in the
connected Ethernet network)
Application of all configurations (Fault And Maintenance Management menu):
<APPLY ALL>
apply all configurations (written in the running configuration)
Confirmation of all configurations (Fault And Maintenance Management menu):
<CONFIRM>
confirm all configurations (written in the startup configuration)
7.1.3 Configuration of the FlexDSL Orion 2 regenerator at the Regenerator Point.
System configuration (Configuration Management menu):
<DEFAULT EVERYTHING>
enable default settings
Line interface configuration (Configuration Management menu):
<MASTER AUTO>
enable automatic detection of the Master/Slave mode
<BASERATE AUTO>
enable automatic detection of the line rate
Configuration of the internal Ethernet switch (Network Management submenu):
<SETIP 10.0.2.202>
set the IP address of the device (depends on the configuration
of the connected network)
<NETMASK 255.0.0.0>
set the subnet mask (this value is the same as in the connected
Ethernet network)
<GATEWAY 10.0.0.101>
– set the default gateway (this value is the same as in the
connected Ethernet network)
Application of all configurations (Fault And Maintenance Management menu):
<APPLY ALL>
apply all configurations (written in the running configuration)
Confirmation of all configurations (Fault And Maintenance Management menu):