User Manual NTU Orion 2
69
4.6.4.11 <RESET> command
The <RESET> command restarts the device.
CP_FMM>RESET
4.6.4.12 <AСO [GROUP ON/OFF])> command
The <AСO> command without additional parameters lists deactivated alarm relays.
CO_FMM>ACO
E1-1, ETHERNET
CO_FMM>
The <ACO [GROUP ON/OFF]> command activated/deactivates the GROUP alarm relays.
Available groups of alarm relays:
GROUP Description
E1-1 or E11 1
st
E1 channel
E1-2 or E12 2
nd
E1 channel
E1-3 or E13 3
rd
E1 channel
E1-4 or E14 4
th
E1 channel
E1 All E1 channels
ETH1 or ETHERNET1 1
st
Ethernet port
ETH2 or ETHERNET2 2
nd
Ethernet port
ETH3 or ETHERNET3 3
rd
Ethernet port
ETH4 or ETHERNET4 4
th
Ethernet port
ETH or ETHERNET All Ethernet ports
DSL1 or XDSL1 1
st
DSL channel
DSL2 or XDSL2 2
nd
DSL channel
DSL3 or XDSL3 3
rd
DSL channel
DSL4 or XDSL4 4
th
DSL channel
DSL or XDSL All DSL channels
RCONF All RCONF alarms
CO_01_FMM>ACO E1-1 OFF
ETHERNET
CO_FMM>
The deactivated alarm relay does not generate urgent or non-urgent alarms (i.e. does not affect
the color of LEDs on the front panel and alarm relay statuses).
For generators, alarm relays DSL and Ethernet can be deactivated.
Note: By default in all configurations, the Ethernet alarm LED is blocked. By typing this
command, the GROUP parameter can not contain several groups of alarm statuses.