User Manual NTU Orion 2
74
4.6.4.23 < POWERMODE [0..5]> command
The < POWERMODE [0..5]> command initialized the desired power mode.
0 Normal unit power consumption mode. No power saving features enabled
1 Normal unit power consumption mode. Power consumption increases very slowly during
startup (soft start). This mode is very useful for remote powered units.
2 CPU clock reduced to 25MHz. Lower power consumption. Soft start enabled.
3 CPU clock reduced to 10MHz. Ethernet port speed reduced to 10Mbit/s. Lower power
consumption. Soft start enabled.
4 CPU clock reduced to 5,5MHz. Ethernet port is switched off. Soft start enabled.
5 CPU clock is adapted to Ethernet port switch. If Ethernet is switched to 100Mbit/s mode,
then CPU clock will be 50/25 MHz, depending of traffic load. If Ethernet power switched
to 10Mbit/s mode, then CPU clock will be 50..10MHz depending of traffic load. If
Ethernet port is not used CPU clock will be reduced to 5,5MHz. Soft start enabled.
4.6.4.24 <TLM > command
The < TLM > command shows the external alarm status of regenerators.
CO_01_FMM>TLM
Distant external alarms status
---------- Line 1 -------- Line 2 -------- Line 3 -------- Line 4 ----
| ALM1 ALM2 ALM3| ALM1 ALM2 ALM3| ALM1 ALM2 ALM3| ALM1 ALM2 ALM3|
----------------------------------------------------------------------
RR01 | off off off | off off off | off off off | off off off |
RR02 | off off off | off off off | off off off | off off off |
RR03 | off off off | off off off | off off off | off off off |
RR04 | off off off | off off off | off off off | off off off |
RR05 | off off off | off off off | off off off | off off off |
RR06 | off off off | off off off | off off off | off off off |
RR07 | off off off | off off off | off off off | off off off |
RR08 | off off off | off off off | off off off | off off off |
RR09 | off off off | off off off | off off off | off off off |
RR10 | off off off | off off off | off off off | off off off |
RR11 | off off off | off off off | off off off | off off off |
RR12 | off off off | off off off | off off off | off off off |
RR13 | off off off | off off off | off off off | off off off |
----------------------------------------------------------------------
CO_01_FMM>
Option: D – shows the reaction of the external alarms of regenerators.
CO_01_FMM>TLM D
Reactions on external alarms
---------- Line 1 -------- Line 2 -------- Line 3 -------- Line 4 ----
| ALM1 ALM2 ALM3| ALM1 ALM2 ALM3| ALM1 ALM2 ALM3| ALM1 ALM2 ALM3|
----------------------------------------------------------------------
RR01 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR02 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR03 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR04 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR05 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR06 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR07 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR08 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR09 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR10 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR11 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR12 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
RR13 | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ | MAJ MAJ MAJ |
----------------------------------------------------------------------
Option C: Clears the status of the TLM table