User Manual NTU Orion 2
76
4.6.4.26 <BERT> command
The <BERT> command allows one to enter the submenu for BER Testing subsystem. Type
<M> to return to the main menu.
4.6.4.27 <H> command
Type
<H> and the monitor lists all available commands in the fault and maintenance sub-menu:
For Stand Alone devices in the BERT Submneu, the following information is displayed
CP_BERT>H
-------------------------------------------------------------------------------
Type 'H [command]' to get additional help on [command]
START Start BERT
STOP Stop BERT
TRACE Trace BERT statistics
SHOW Show BERT statistics once
RES Reset BERT statistics
SET [E11-E12] [INT/EXT] Set BERT interface
PATD [2En/bitstring] Set BERT pattern
CONF Display current BERT configuration
CONNECT [N:[1-13/R]] Establish connection to remote unit
LINK [NN] Establish local connection
LINKCLEAR Exit all local connections
M Return to Fault and Maintenance Menu
H Show available commands
-------------------------------------------------------------------------------
CP_BERT>
4.6.4.28 <START> command
This command starts the internal BER tester.
4.6.4.29 <STOP> command
This command stops the internal BER tester.
4.6.4.30 <TRACE > command
This command shows continuously the actual status of the BERT.
--------------------------------------------------------------------------------
BERT status G.826
--------------------------------------------------------------------------------
Sync : Sync loss Errors : 0
Alarms : ALL 0s Errored seconds : 0
Bitrate TX : 0 Severely errored seconds : 0
Bitrate RX : 64000 Background block errors : 0
Bit errors : 0 ESR [%] : 0.00
Pattern time : 0 SESR[%] : 0.00
Error ratio : 0 BBER [%] : 0.00
No errors for : 0 Available time : 0
Total test time : 60 Unavailable time : 60
--------------------------------------------------------------------------------
1. Stop BERT 4. Inject error
2. Exit trace
3. Reset BERT results
--------------------------------------------------------------------------------