EasyManua.ls Logo

FlexDSL ORION 2 - BERT> Command; H> Command; START> Command; STOP> Command

FlexDSL ORION 2
115 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual NTU Orion 2
76
4.6.4.26 <BERT> command
The <BERT> command allows one to enter the submenu for BER Testing subsystem. Type
<M> to return to the main menu.
4.6.4.27 <H> command
Type
<H> and the monitor lists all available commands in the fault and maintenance sub-menu:
For Stand Alone devices in the BERT Submneu, the following information is displayed
CP_BERT>H
-------------------------------------------------------------------------------
Type 'H [command]' to get additional help on [command]
START Start BERT
STOP Stop BERT
TRACE Trace BERT statistics
SHOW Show BERT statistics once
RES Reset BERT statistics
SET [E11-E12] [INT/EXT] Set BERT interface
PATD [2En/bitstring] Set BERT pattern
CONF Display current BERT configuration
CONNECT [N:[1-13/R]] Establish connection to remote unit
LINK [NN] Establish local connection
LINKCLEAR Exit all local connections
M Return to Fault and Maintenance Menu
H Show available commands
-------------------------------------------------------------------------------
CP_BERT>
4.6.4.28 <START> command
This command starts the internal BER tester.
4.6.4.29 <STOP> command
This command stops the internal BER tester.
4.6.4.30 <TRACE > command
This command shows continuously the actual status of the BERT.
--------------------------------------------------------------------------------
BERT status G.826
--------------------------------------------------------------------------------
Sync : Sync loss Errors : 0
Alarms : ALL 0s Errored seconds : 0
Bitrate TX : 0 Severely errored seconds : 0
Bitrate RX : 64000 Background block errors : 0
Bit errors : 0 ESR [%] : 0.00
Pattern time : 0 SESR[%] : 0.00
Error ratio : 0 BBER [%] : 0.00
No errors for : 0 Available time : 0
Total test time : 60 Unavailable time : 60
--------------------------------------------------------------------------------
1. Stop BERT 4. Inject error
2. Exit trace
3. Reset BERT results
--------------------------------------------------------------------------------