User Manual NTU Orion 2
54
4.6.1.1 System invitation
The following format of the system invitation is used in all menus: <cc>_<addr>_<sf>>,
сс is the device mode [RR – regenerator, CO – Master; CP – Slave; CX – a modem with both
types of interfaces, CA – a device with the automatic selection of the DSL line parameters
(<MASTER>, <BASERATE>, <PAM> and <ANNEX>)];
addr is the address of the regenerator in the system (only for regenerators), or a device in the
shelf (only for Subrack devices);
sf is the short form of the current menu (MM – Main Menu; PM – Performance Management;
FMM – Fault and Maintenance Management; CM – Configuration Management).
For example:
CO_PM> - the device is in the Master mode ( the Performance Management menu).
4.6.2 General Commands
4.6.2.1 <H> command
After the <H> command is entered the device displays the help menu.
4.6.2.2 <CONNECT N:1..13/R> command
The <CONNECT N:1..13/R> commands initializes the management of the remote device.
The parameter N sets the number of the xDSL channel, over which the connection is initialized.
In single-channel systems the parameter N can be absent.
Notes:
1. The <CONNECT R> command in the Slave mode is only available if the Master device
can be configured locally at this instant.
2. The <CONNECT N> (N=1..13) command initializes the management of the remote
regenerator. The <CONNECT N> command is available only in the Master mode.
3. This command is not provisioned for regenerators.
4. If the channel of remote management is blocked (for example, a message or a table are
not displayed completely), press Enter.
4.6.2.3 <LINK [SN/00/FE]> > command
The < LINK [SN/00/FE]> command establishes connection to specified unit over the RS232
monitor port.
• SN - Specifies slot number of a subrack unit in cassette to establish connect with. If the
backplane is busy "LINK ERROR" message will be issued by unit. If specified cassette slot
is free (or no response in 1.5 first seconds) the same message will be issued. For subrack
units SN should not be 00.
• 00 - (double zero) Switches on Monitor connector control mode for Minirack and standalone
units. In this mode all typed characters will be translated to Monitor connector.
• FE - (for ever) Switches on Monitor connector control mode for common CLI RS232 units. In
this mode all typed characters will be translated to Monitor connector. The connection will be
established until a terminal timeout appears.