4.6.4 Fault and maintenance management menu
After typing “2” in the main menu and pressing enter, the following message is displayed:
Fault and maintenance management activated
Enter <M> to return to MAIN, or <H> for HELP information
4.6.4.1 <H> command
Type
<H> and the monitor lists all available commands in the fault and maintenance sub-menu:
For Stand Alone devices, the following information is displayed:
CO_FMM> H
-------------------------------------------------------------------------------
Type 'H [command]' to get additional help on [command]
NM Trace xDSL noise margin
STATUS Show current DSL working parameters
STATUS T Show current DSL working parameters continuously
STATUS L Show current DSL and LINK payload parameters
STATUS ETH Show Ethernet status
MACTABLE Print MAC table
MACTABLE C Clear MAC table
LOOP1 [ON/OFF] [N] Start/stop local loopback at Nth E1 interface
LOOP2 [N:[A/R]] [ON/OFF] Starts/stops the remote loopback at Nth xDSL interface
ALARM Display alarms
ALARM T Display alarms continuously
ACO Show alarm cutoff configuration
ACO [GROUP] [ON/OFF] Change alarm indication for alarm group GROUP
STARTAL [N] Toggles Nth xDSL channel the analog loopback ON/OFF
RESTART [N] Restart Nth xDSL channel
RESET Reset modem
SOFTUPDATE Update software
SOFTCONFIRM Confirm uploaded software
SOFTINFO List loaded software
APPLY [ALL/GROUP] Apply changes to running configuration
CONFIRM Confirm running configuration
BACKUP Backup running configuration
RESTORE Restore startup configuration from backup
DIFF [N/R/S/B] [N/R/S/B] Show difference between configurations
DUMP [N/R/S/B] Dump selected configuration
LOAD Load configuration via XModem
POWERMODE [0-5] Set device power consumption mode
TLM Show external alarm status
TLM D Show external alarm reaction
TLM S [N:Rnn-Rkk] [ABC] Set up external alarm reaction
TLM C Clear external alarm table
CONNECT [N:[1-13/R]] Establish connection to remote unit
LINK [NN] Establish local connection
LINKCLEAR Exit all local connections
BERT BERT configuration menu
M Return to Main Menu
H Show available commands
-------------------------------------------------------------------------------
CO_FMM>