User Manual NTU Orion 2
44
3.5.2.3 SNMP
The SNMP protocol is used to monitor statuses, to configure and manage FlexDSL Orion 2
devices. In this case, the control computer should have a special SNMP program installed.
FlexDSL Orion 2 devices support SNMP v1.
The following management information bases (MIBs) are supported:
• RFC1213-MIB – a standard MIB for all devices, supporting MIB II and described in RFC-
1213, is fully supported.
• IF-MIB – MIB descriptions of interfaces, described in RFC-2863, are fully supported.
• NATEKS-MIB – a MIB for the Nateks equipment, is fully supported.
• DS1-MIB – a MIB describing E1 streams, RFC-2495, is partially supported.
Traps are sent by the device into two addresses. The following traps are supported:
• coldStart (RFC1215).
• authenticationFailure (RFC1215).
• linkUp (RFC1213-MIB, IF-MIB).
• linkDown (RFC1213-MIB, IF-MIB).
• dsx1LineStatusChange (DS1-MIB).
• Specific Alarm Traps (nateks.mib)
The SNMP protocol to be operable, the SNMP agent should be installed. The COMMUNITY
command (configuration of the community parameter of SNMP messages) and the TRAPIP
command (configuration of IP-addresses for traps) are used to configure the SNMP agent. The
IP-address and other network configurations of the SNMP agent coincide with network
configurations of the device (see SETIP, NETMASK, GATEWAY commands and the NET sub-
menu).
The Nateks Company has a registered OID number equal to 4249.
Prefix: iso.org.dod.internet.private.enterprise (1.3.6.1.4.1)
4249
NATEKS Ltd.
Alex Rousnak
Alex@nateks.ru
The content of this label is described by the Nateks-MIB. By using the variables described in the
Nateks-MIB, one can perform the following actions:
• to view general information about the device.
• to monitor the general status of the device (presence of alarms).
• to reboot the device.