EasyManua.ls Logo

FlexDSL ORION 2 - Power Supply and Environmental Conditions

FlexDSL ORION 2
115 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual NTU Orion 2
115
8.2 Power Supply
Specification ETSI ETS 300 132-2
Voltage 1 x 38 ..72V
DC
over Molex type safety approved connector
38..118Vdc over xDSL
Voltage for -24V models 1 x 18..72V
DC
over Molex type safety approved connector
No remote power feeding allowed
Power Consumption
(Powermode = 0)
Typ. 4.00W FG-PAM-SAN-E1B/Eth,V50
Typ. 4.50W FG-PAM-SA2N-2E1B/Eth,V51
Typ. 4.50W FG-PAM-RAIL2N-2E1B/Eth, V51
Typ. 2.50W FG-PAM-SAN-Eth,V52
Typ. 3.20W FG-PAM-SA2N-Eth,V53
Typ. 4.10W FG-PAM-SA4N-Eth,V54
8.3 Environmental
8.3.1 Climatic Conditions
Storage: ETS 300 019-1-1 Class 1.2
(-25°C … +55°C)
Transportation: ETS 300 019-1-2 Class 2.3
(-40°C … +70°C)
Operation: ETS 300 019-1-3 Class 3.2
(-5°C … +45°C)
Higher Operation Temperaturrange available on request.
8.3.2 Safety / EMC
According to:
IEC 60950-1:2005
EN 60950-1:2006
EN 55022, Class B
EN 300386
EN 50121-4
8.4 Physical Dimensions and Weight
Dimensions Plastic: 220(W)x155(D)x50(H) mm
Weight: 0.5 kg
Dimensions RAIL: 216(W)x165(D)x42.5(H) mm
Weight: 1.00 kg