GN
No Default.
N/A.
Get Net Value.
GO No Default. N/A. Get Peak-to-Peak Value.
GS No Default. N/A. Get ADC Sample.
GT
No Default.
N/A.
Get Tare Value.
GV
No Default.
N/A.
Get Valley Value.
GW No Default. N/A. Get Data String (Net, Gross, Status).
H’n’
(H0/H1)
999999dec. ±999999dec. Hysteresis Set-Points.
HT
Zero.
0…65535dec.
Hold-Time for All Set-Points.
HW
No Default.
N/A.
Hold Weight - Broadcast Message.
IN
No Default.
0000…0011bin.
External Input State.
IO
Zero.
0000…0011bin.
External Output State.
IS No Default. N/A. Get System Status.
IZ
No Default.
N/A.
Correction of System Zero.
MR
Zero.
0…1dec.
Set Multi-Range/Multi-Interval.
MT Zero. 0…3000dec. Measuring Time for Averaging (ms).
NA
1.
1…127dec.
CAN Network Address.
NR
1.
0…65535dec.
No-Motion Range.
NS 1
1.
1…127dec.
CAN Network Address (as NA).
NS 2
500.
10, 20, 50, 125, 250,
500, 800, 1000dec.
CAN Network Speed (kBits/sec).
NT
1000.
1…65535dec.
No-Motion Time-Period (ms).
OF Zero. 0…3dec.
Output Format of Data String GL &
GW.
OM Zero. 0000…0011bin. External Output Mask.
OP
No Default.
1…255dec.
Open Communications.
PD1
No Default.
0, 1, 2, 3, 4, 8, 12dec.
Pre-Fill Mode.
PD2
No Default.
0…50dec.
In-Flight Correction Value.
PD3 N/A. 0..65535dec.
Average Time Zero Check Load Cell.
PD4
N/A.
0..65535dec.
Delay Time Tare Average Value.
PD5
N/A.
0..65535dec.
Average Time Tare Weight Value.
PD6
N/A.
0..65535dec.
Delay Time After Pre-Filling Value.
PD7 N/A.
0..65535dec.
Blanking Time After Coarse Valve
Shuts Off.
PD8 N/A.
0..65535dec.
In-Flight Delay Time After Fine Valve
Shuts Off.
PD9 N/A.
0..65535dec.
Dosed Weight Average Time.
PD10
N/A.
0..99999dec.
Zero Tolerance Value.
PD11
N/A.
0..99999dec.
Tare Reference Weight Value.
PD12
N/A.
0..99999dec.
Tare Weight Tolerance Value.
PD13 N/A.
0..99999dec.
Pre-Fill Level 1st Setpoint Value.